2a7e

From Proteopedia

(Difference between revisions)
Jump to: navigation, search
m (Protected "2a7e" [edit=sysop:move=sysop])
Line 1: Line 1:
-
[[Image:2a7e.png|left|200px]]
+
==On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength==
 +
<StructureSection load='2a7e' size='340' side='right' caption='[[2a7e]], [[Resolution|resolution]] 1.66&Aring;' scene=''>
 +
== Structural highlights ==
 +
<table><tr><td colspan='2'>[[2a7e]] is a 1 chain structure. Full crystallographic information is available from [http://oca.weizmann.ac.il/oca-bin/ocashort?id=2A7E OCA]. For a <b>guided tour on the structure components</b> use [http://oca.weizmann.ac.il/oca-docs/fgij/fg.htm?mol=2A7E FirstGlance]. <br>
 +
</td></tr><tr><td class="sblockLbl"><b>Resources:</b></td><td class="sblockDat"><span class='plainlinks'>[http://oca.weizmann.ac.il/oca-docs/fgij/fg.htm?mol=2a7e FirstGlance], [http://oca.weizmann.ac.il/oca-bin/ocaids?id=2a7e OCA], [http://www.rcsb.org/pdb/explore.do?structureId=2a7e RCSB], [http://www.ebi.ac.uk/pdbsum/2a7e PDBsum]</span></td></tr>
 +
<table>
 +
<div style="background-color:#fffaf0;">
 +
== Publication Abstract from PubMed ==
 +
Complete and highly redundant data sets were collected at different wavelengths between 0.80 and 2.65 A for a total of ten different protein and DNA model systems. The magnitude of the anomalous signal-to-noise ratio as assessed by the quotient R(anom)/R(r.i.m.) was found to be influenced by the data-collection wavelength and the nature of the anomalously scattering substructure. By utilizing simple empirical correlations, for instance between the estimated deltaF/F and the expected R(anom) or the data-collection wavelength and the expected R(r.i.m.), the wavelength at which the highest anomalous signal-to-noise ratio can be expected could be estimated even before the experiment. Almost independent of the nature of the anomalously scattering substructure and provided that no elemental X-ray absorption edge is nearby, this optimal wavelength is 2.1 A.
-
{{STRUCTURE_2a7e| PDB=2a7e | SCENE= }}
+
On the routine use of soft X-rays in macromolecular crystallography. Part III. The optimal data-collection wavelength.,Mueller-Dieckmann C, Panjikar S, Tucker PA, Weiss MS Acta Crystallogr D Biol Crystallogr. 2005 Sep;61(Pt 9):1263-72. Epub 2005, Aug 16. PMID:16131760<ref>PMID:16131760</ref>
-
===On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength===
+
From MEDLINE&reg;/PubMed&reg;, a database of the U.S. National Library of Medicine.<br>
-
 
+
</div>
-
{{ABSTRACT_PUBMED_16131760}}
+
== References ==
-
 
+
<references/>
-
==About this Structure==
+
__TOC__
-
[[2a7e]] is a 1 chain structure. Full crystallographic information is available from [http://oca.weizmann.ac.il/oca-bin/ocashort?id=2A7E OCA].
+
</StructureSection>
-
 
+
-
==Reference==
+
-
<ref group="xtra">PMID:016131760</ref><references group="xtra"/>
+
[[Category: Mueller-Dieckmann, C.]]
[[Category: Mueller-Dieckmann, C.]]
[[Category: Panjikar, S.]]
[[Category: Panjikar, S.]]

Revision as of 07:05, 9 June 2014

On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- The Optimal Data Collection Wavelength

2a7e, resolution 1.66Å

Drag the structure with the mouse to rotate

Proteopedia Page Contributors and Editors (what is this?)

OCA

Views
Personal tools
Navigation
Toolbox